DIMENSIONS
200 x 150 x 86 (mm)
7.87 x 5.91 -x 3.39 (inch)
INPUT SPEC
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY: 47 ~ 63 Hz
INPUT CURRENT: 9.0A @115V; 5 A @ 230 VAC
INRUSH CURRENT: 35A @ 115V; 75A @230 VAC
DC OUTPUT SPEC
Output Voltage | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 1 | 32 | ± 5% | ± 1% | 50mV |
+12V | 1 | 65 | ± 5% | ± 1% | 120mV |
-12V | 0 | 0.8 | ±5% | ± 1% | 120mV |
+3.3V | 1.0 | 32 | ±5% | ± 1% | 50mV |
+5VSB | 0.1 | 3.5 | ± 5% | ± 1% | 50mV |
REMARKS:
1. TOTAL OUTPUT OF +5V & +3.3V NOT EXCEED 190W
2. TOTAL OUTPUT POWER NOT EXCEED 800W
TEMPERATURE RANGE:
OPERATING: 0℃ ~ 40℃
STORAGE: –20℃ ~ 80℃
HOLD UP TIME:
DC OUTPUT 12V MUST BE MAINTAIN 16 ms IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
EFFICIENCY:
TYPICAL >80% AT 115V, 25%~100% MAX LOAD
POWER GOOD SIGNAL:
ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER POWER PROTECTION:
100~160%
OVER VOLTAGE PROTECTION:
+5V→5.7~6.5V, +3.3V→3.9~4.7V, +12V→13.3~14.3V
SHORT CIRCUIT PROTECTION:
+12V, -12V, +5VSB
EMI NOISE FILTER:
FCC CLASS B, CISPR22 CLASS B
FAULTY ALARM METHODS:
LED, BUZZER, TTL SIGNAL
SAFETY:
TO MEET UL, CUL, TUV, RFI/EMI STANDARDS
REMOTE ON/OFF CONTROL
COOLING:
TWO 40mm DC FANS (MODULE)
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.